MRC |
Requirement Statement |
Characteristics |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES DC RESISTIVE LOAD |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |
ABMK |
OVERALL WIDTH |
1.590 INCHES MAXIMUM |
ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
28.0 DC |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE MOUNTING FACILITY |
ABHP |
OVERALL LENGTH |
2.495 INCHES MAXIMUM |
AKDX |
WINDING QUANTITY |
1 |
TTQY |
TERMINAL TYPE AND QUANTITY |
11 PIN ALL FUNCTIONS |
ABKW |
OVERALL HEIGHT |
1.380 INCHES MAXIMUM |
APCN |
COIL QUANTITY |
1 |
CRXH |
TIME DELAY |
0.30 SECONDS NOMINAL FIXED RELEASE TIME |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED STUD SINGLE MOUNTING FACILITY |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.940 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE MOUNTING FACILITY |
AAJD |
THREAD CLASS |
2A SINGLE MOUNTING FACILITY |
APNP |
DUTY TYPE |
CONTINUOUS |