| Mfg. Part # | Mfg. Name | CAGE | RNCC | RNVC | ISC | MSDS | SADC | DAC | HCC |
|---|---|---|---|---|---|---|---|---|---|
| 106311-44 | ROLM CORP | 14345 | C | 1 | B | D | |||
| 1648-775 | WOODWARD GOVERNOR COMPANY | 31361 | 5 | 9 | B | ||||
| 287-990024-326 | CMC ELECTRONICS INC | 38753 | 5 | 1 | B | ||||
| 5E4720/05-2741 | HAMILTON SUNDSTRAND CORPORATION | 73030 | C | 1 | B | F | |||
| 724-0630-690 | ROCKWELL COLLINS INC. | 95105 | C | 1 | B | D | |||
| 724-0639-370 | ROCKWELL COLLINS INC. | 13499 | 5 | 9 | B | ||||
| 912-3103-0661 | SELEX GALILEO SPA | A0810 | 5 | 2 | B | ||||
| 912-3103-0661 | ALENIA AERONAUTICA SPA | A0019 | 5 | 2 | B | ||||
| 912-3103-0661 | ALENIA SISTEMI DIFESA SPA | A0307 | 5 | 9 | B | ||||
| 937-220-4274 | NORTHROP GRUMMAN SYSTEMS CORPORATION | 95542 | E | 8 | B | ||||
| 937-220-4274 | MEPCO/ELECTRA INC | 80031 | E | 8 | B | ||||
| 937-220-4274 | TRW INC | 75042 | E | 8 | B | ||||
| CCH2741F | ROCKWELL AUTOMATION INC. | 01121 | C | 1 | B | F | |||
| MF4CC2741F | NORTH AMERICAN PHILIPS CORP | 19701 | C | 1 | B | D | |||
| MIL-R-55182/1 | MILITARY SPECIFICATIONS | 81349 | 4 | 1 | B | ||||
| RLR07C3092FM | MILITARY SPECIFICATIONS | 81349 | 5 | 9 | B | ||||
| RN55C2741F | CMC ELECTRONICS INC | 90073 | C | 1 | B | N | |||
| RN55C2741FS | MILITARY SPECIFICATIONS | 81349 | C | 1 | B | N | |||
| RN55D2761F | MILITARY SPECIFICATIONS | 81349 | 5 | 9 | B | ||||
| RNC55H2741FM | MILITARY SPECIFICATIONS | 81349 | 5 | 9 | B | ||||
| RNC55H2741FP | MILITARY SPECIFICATIONS | 81349 | 5 | 9 | B | ||||
| RNC55H2741FR | MILITARY SPECIFICATIONS | 81349 | 5 | 9 | B | ||||
| RNC55H2741FS | MILITARY SPECIFICATIONS | 81349 | 2 | 2 | B | ||||
| RNC55J2741FS | BAE SYSTEMS INFORMATION AND | 19397 | 5 | 1 | B | ||||
| ST859618-243 | DELCO ELECTRONICS CORP | 99974 | C | 1 | B | D |
| MRC | Requirement Statement | Characteristics |
|---|---|---|
| SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-55182/1 |
| AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 175.0 |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
| AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
| SR-1 | SPEC/STD CONTROLLING DATA | |
| AARG | RELIABILITY INDICATOR | ESTABLISHED |
| AAPP | ELECTRICAL RESISTANCE | 2.740 KILOHMS |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-55182/1 GOVERNMENT SPECIFICATION |
| ABJT | TERMINAL LENGTH | 1.250 INCHES NOMINAL |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
| AARB | TERMINAL TYPE | WIRE LEAD |
| STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
| ABPM | BODY DIAMETER | 0.109 INCHES NOMINAL |
| SR-1 | MANUFACTURERS CODE | 81349 |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
| PKWT | III UNPACKAGED UNIT WEIGHT | 0.300 GRAMS |
| CBME | (NON-CORE DATA) CUBIC MEASURE | 0.002 CUBIC INCHES |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| ADAQ | BODY LENGTH | 0.250 INCHES NOMINAL |
| AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0 TO 50.0 |
| AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C |
| SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RNC55H2741FS |