MRC |
Requirement Statement |
Characteristics |
CRBZ |
WINDING OPERATING CURRENT |
150.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE GROUP |
ADAT |
BODY WIDTH |
5.875 INCHES NOMINAL |
ADAQ |
BODY LENGTH |
6.625 INCHES NOMINAL |
AAJF |
(NON-CORE DATA) THREAD DIRECTION |
RIGHT-HAND |
AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
SR-5 |
THE MANUFACTURERS DATA |
|
CMLP |
THREAD QUANTITY PER INCH |
20 SINGLE GROUP |
SR-5 |
MANUFACTURERS CODE |
3B150 |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
5.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AAJD |
(NON-CORE DATA) THREAD CLASS |
2A |
SR-5 |
DESIGN CONTROL REFERENCE |
292-5094G1ISSUE4 |
ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL SINGLE COMPONENT |
AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
5.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAU |
BODY HEIGHT |
4.750 INCHES NOMINAL |
ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 4.30 AC KILOVOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 SOLDER STUD AND 2 STANDOFF INSULATOR |