MRC |
Requirement Statement |
Characteristics |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
APNQ |
ARC QUENCHING METHOD |
AIR |
ADZC |
ENVIRONMENTAL PROTECTION |
DUSTPROOF |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
ABHP |
OVERALL LENGTH |
2.900 INCHES MAXIMUM |
CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
51.0 MILLIAMPERES DC SINGLE WINDING |
APNA |
WINDING DC RESISTANCE RATING |
472.0 OHMS NOMINAL SINGLE WINDING |
AFJN |
III FRAGILITY FACTOR |
MODERATELY RUGGED |
CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
AFRG |
III CONTACT MATERIAL |
SILVER |
PMLC |
III PRECIOUS MATERIAL AND LOCATION |
CONTACTS SILVER |
TTQY |
TERMINAL TYPE AND QUANTITY |
11 QUICK DISCONNECT, MALE ALL FUNCTIONS |
AKSL |
III PURPOSE FOR WHICH DESIGNED |
GENERAL |
AKDX |
WINDING QUANTITY |
1 |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
BBRG |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
120.0 AC AND 28.0 DC |
PRMT |
III PRECIOUS MATERIAL |
SILVER |
APCN |
COIL QUANTITY |
1 |
ABMK |
OVERALL WIDTH |
1.531 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
CRXH |
TIME DELAY |
0.015 SECONDS NOMINAL FIXED OPERATE TIME 0.01 SECONDS NOMINAL FIXED RELEASE TIME |
ADTV |
III CASE MATERIAL |
PLASTIC |
CBME |
III CUBIC MEASURE |
6.242 CUBIC INCHES |
CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABTD |
MOUNTING SLOT WIDTH |
0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW |
OVERALL HEIGHT |
1.406 INCHES MAXIMUM |
APNP |
DUTY TYPE |
CONTINUOUS |