Home > Capacitor, Fuse, Circuit Breaker > FSC 5915 > 5915-00-501-4155

5915-00-501-4155, 5915005014155 NSN Information

Request for Quote

Manufacturer Part Number(s):ERLC1063, GA51583, SC-C-63429

FSC NIIN ITEM NAME
5915 005014155 FILTER,BAND PASS
INC ESDC HMIC
0020 P

5915-00-501-4155 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
ERLC1063 ELECTRONIC RESEARCH CO 13571 5 2 2
GA51583 AMERICAN TELEPHONE AND TELEGRAPH CO 64959 5 9 2
SC-C-63429 AEROFLEX LABORATORIES INC 54832 5 2 2
SC-C-63429 US ARMY COMMUNICATIONS & 80063 3 2 2

5915-00-501-4155 Characteristics

MRC Requirement Statement Characteristics
CRBB FREQUENCY BAND WIDTH PER FUNCTION 116.00 KILOHERTZ BLANK AND 124.00 KILOHERTZ BLANK
ADAT BODY WIDTH 1.812 INCHES NOMINAL
CQDW FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 TAB, SOLDER LUG INPUT 1ST FUNCTION 1 TAB, SOLDER LUG OUTPUT 2ND FUNCTION 2 TAB, SOLDER LUG GROUND 3RD FUNCTION
AKEJ MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNF
CQRG III BODY MATERIAL METAL
ADAQ BODY LENGTH 4.844 INCHES NOMINAL
AHAJ REFERENCE FREQUENCY PER FUNCTION 120.0 KILOHERTZ BLANK
STYL STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
AFSV III AVERAGE LIFE RATING IN HOURS 10000.0
CQDZ III MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE 500.0 VOLTS AT SEA LEVEL
CQFC III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION 112.00 KILOHERTZ BLANK AND 116.00 KILOHERTZ BLANK AND 124.00 KILOHERTZ BLANK AND 128.00 KILOHERTZ BLANK
ADAU BODY HEIGHT 2.531 INCHES NOMINAL
ABKW OVERALL HEIGHT 3.062 INCHES NOMINAL
AFGA III OPERATING TEMP RANGE -65.0 TO 185.0 DEG FAHRENHEIT
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED STUD
AKNA INCLOSURE TYPE HERMETICALLY SEALED
AHAU INPUT IMPEDANCE PER FUNCTION W/LOAD 130.0 OHMS BLANK
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 4.188 INCHES NOMINAL
AHAV OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT 40.0 KILOHMS BLANK
CQJX NOMINAL THREAD SIZE 0.190 INCHES
CRBC III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS 65.0 MINIMUM BLANK AND 40.0 MINIMUM BLANK AND 40.0 MINIMUM BLANK AND 65.0 MINIMUM BLANK
CQDR INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS 4.0 BLANK
AECR III VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 55.0