| MRC |
Requirement Statement |
Characteristics |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
95.00 AC VOLTS MINIMUM AND 130.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY 116.80 AC VOLTS MINIMUM AND 119.20 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| AXGY |
MOUNTING METHOD |
FLANGE AND UNTHREADED HOLE SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
8.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| SR-5 |
DESIGN CONTROL REFERENCE |
20-10-015 |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| SR-5 |
THE MANUFACTURERS DATA |
|
| ABTB |
MOUNTING HOLE DIAMETER |
0.250 INCHES NOMINAL SINGLE GROUP |
| ADAQ |
BODY LENGTH |
5.564 INCHES NOMINAL |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 WIRE LEAD |
| ACZB |
FREQUENCY RATING |
60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
5.063 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ADAU |
BODY HEIGHT |
3.500 INCHES NOMINAL |
| ADAT |
BODY WIDTH |
2.625 INCHES NOMINAL |
| ACZF |
MAXIMUM TRANSFORMER POWER RATING |
15.0 VOLT-AMPERE SINGLE COMPONENT |
| SR-5 |
MANUFACTURERS CODE |
55814 |