MRC |
Requirement Statement |
Characteristics |
ABMK |
OVERALL WIDTH |
3.410 INCHES NOMINAL |
ABHP |
OVERALL LENGTH |
3.410 INCHES NOMINAL |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.215 INCHES MINIMUM AND 0.228 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |
ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
ABKW |
OVERALL HEIGHT |
4.250 INCHES MAXIMUM |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
AFJN |
III FRAGILITY FACTOR |
MODERATELY RUGGED |
CBME |
III CUBIC MEASURE |
49.419 CUBIC INCHES |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKSL |
III PURPOSE FOR WHICH DESIGNED |
GENERAL |
AKDX |
WINDING QUANTITY |
1 |
BBRG |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
APCN |
COIL QUANTITY |
1 |
CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
100.0 AMPERES DC RESISTIVE LOAD 100.0 AMPERES DC INDUCTIVE LOAD |
TTQY |
TERMINAL TYPE AND QUANTITY |
11 THREADED STUD ALL FUNCTIONS |
APNP |
DUTY TYPE |
CONTINUOUS |