Requirement Statement |
Characteristics |
APNQ |
ARC QUENCHING METHOD |
AIR |
ABHP |
OVERALL LENGTH |
2.500 INCHES MAXIMUM |
CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |
ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
AJSS |
FREQUENCY IN HERTZ |
60.0 NOMINAL |
CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
20.0 AMPERES AC AND 20.0 AMPERES DC RESISTIVE LOAD 20.0 AMPERES AC AND 15.0 AMPERES DC INDUCTIVE LOAD 5.0 AMPERES AC AND 5.0 AMPERES DC LAMP LOAD 20.0 AMPERES AC AND 20.0 AMPERES DC MOTOR LOAD |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
ABMK |
OVERALL WIDTH |
1.465 INCHES MAXIMUM |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.062 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN |
III FRAGILITY FACTOR |
MODERATELY RUGGED |
ADTV |
III CASE MATERIAL |
METAL |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.173 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKSL |
III PURPOSE FOR WHICH DESIGNED |
GENERAL |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
AKDX |
WINDING QUANTITY |
1 |
CRXH |
TIME DELAY |
0.02 SECONDS MAXIMUM FIXED OPERATE TIME 0.01 SECONDS MAXIMUM FIXED RELEASE TIME |
BBRG |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
APCN |
COIL QUANTITY |
1 |
ABKW |
OVERALL HEIGHT |
2.400 INCHES MAXIMUM |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CBME |
III CUBIC MEASURE |
8.790 CUBIC INCHES |
TTQY |
TERMINAL TYPE AND QUANTITY |
8 SCREW ALL FUNCTIONS |
APNP |
DUTY TYPE |
CONTINUOUS |