MRC |
Requirement Statement |
Characteristics |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKW |
OVERALL HEIGHT |
4.125 INCHES NOMINAL |
ABMK |
OVERALL WIDTH |
2.844 INCHES NOMINAL |
AEHZ |
III MAXIMUM OPERATING TEMP |
80.0 DEG CELSIUS |
SR-5 |
MANUFACTURERS CODE |
49956 |
ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
AAJF |
(NON-CORE DATA) THREAD DIRECTION |
RIGHT-HAND |
CWJS |
WINDING OPERATING VOLTAGE |
230.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY 6.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
SR-5 |
THE MANUFACTURERS DATA |
|
CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
AAJD |
(NON-CORE DATA) THREAD CLASS |
2A |
CRBZ |
WINDING OPERATING CURRENT |
3.5 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
TTQY |
TERMINAL TYPE AND QUANTITY |
5 TAB, SOLDER LUG |
SR-5 |
DESIGN CONTROL REFERENCE |
292-4640G1 |
ADAQ |
BODY LENGTH |
3.531 INCHES NOMINAL |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.562 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
CQLC |
(NON-CORE DATA) WINDING TAP LOCATION |
CENTER TAP |
ADAU |
BODY HEIGHT |
3.250 INCHES NOMINAL |