Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-409-5577

5925-00-409-5577, 5925004095577 NSN Information

Request for Quote

Manufacturer Part Number(s):AP12-1-5-0-203, AP12-745-1, SMC2015883

FSC NIIN ITEM NAME
5925 004095577 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-409-5577 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
AP12-1-5-0-203 SENSATA TECHNOLOGIES MARYLAND INC 81541 5 2 3
AP12-745-1 SENSATA TECHNOLOGIES MARYLAND INC 81541 3 2 3
SMC2015883 US ARMY COMMUNICATIONS & 80063 5 2 3

5925-00-409-5577 Characteristics

MRC Requirement Statement Characteristics
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
CQJX NOMINAL THREAD SIZE 0.375 INCHES
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
ADTV CASE MATERIAL METAL
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
THSD THREAD SERIES DESIGNATOR UNEF
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.780 INCHES MAXIMUM
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
CPRX ACTUATOR POSITION DESIGNATION BETWEEN POLE ONE AND TWO
CPRQ RESET METHOD MANUAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING W/PANEL SEAL
AAJE THREAD PITCH DIAMETERS 0.3503 TO 0.3537 INCHES
ADAQ BODY LENGTH 1.500 INCHES MAXIMUM
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 0.625 INCHES NOMINAL
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 500.0 DC ALL LOCATIONS
CMLP THREAD QUANTITY PER INCH 32
ABXD BUSHING LENGTH 0.375 INCHES MAXIMUM
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 115.0 ALL LOCATIONS
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.875 INCHES NOMINAL
AKPX POLE QUANTITY 2
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE HOOK
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 20.0 AMPERES DC ALL LOCATIONS
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 50.0 DC ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 0.030 NOMINAL AT 200 PCT AND 0.020 NOMINAL AT 300 PCT ALL LOCATIONS
ADAT BODY WIDTH 1.250 INCHES MAXIMUM