| MRC |
Requirement Statement |
Characteristics |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION 1 THREADED STUD OUTPUT 2ND FUNCTION 1 THREADED STUD GROUND 3RD FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
5.0 1ST RADIO INTERFERENCE 1ST FUNCTION 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION 5.0 3RD RADIO INTERFERENCE 3RD FUNCTION 5.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
60.0 1ST RADIO INTERFERENCE 1ST FUNCTION 60.0 2ND RADIO INTERFERENCE 2ND FUNCTION 60.0 3RD RADIO INTERFERENCE 3RD FUNCTION 60.0 4TH RADIO INTERFERENCE 4TH FUNCTION |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
208.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION 208.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION 208.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION 208.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBP |
III INPUT TERMINAL IDENTIFICATION |
M83723-22R2410N |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AHBL |
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION |
INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION |
| AHBN |
III INPUT TERMINAL MANUFACTURER CODE |
81349 |