MRC |
Requirement Statement |
Characteristics |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.112 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
CQJX |
NOMINAL THREAD SIZE |
0.112 INCHES SINGLE MOUNTING FACILITY |
CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
6.7 MILLIAMPERES DC SINGLE WINDING |
ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE MOUNTING FACILITY |
APNA |
WINDING DC RESISTANCE RATING |
7.8 KILOHMS NOMINAL SINGLE WINDING |
ADAV |
OVERALL DIAMETER |
1.000 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
8 PIN ALL FUNCTIONS |
CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
CMLP |
THREAD QUANTITY PER INCH |
40 SINGLE MOUNTING FACILITY |
AKDX |
WINDING QUANTITY |
1 |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED STUD SINGLE MOUNTING FACILITY |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 26.5 DC |
APCN |
COIL QUANTITY |
1 |
AYSC |
PILE-UP MAIN CONTACT FORM ARRANGEMENT |
2C |
ABHP |
OVERALL LENGTH |
1.310 INCHES NOMINAL |
AAJD |
THREAD CLASS |
2A SINGLE MOUNTING FACILITY |
APNP |
DUTY TYPE |
CONTINUOUS |