Home > Capacitor, Fuse, Circuit Breaker > FSC 5925 > 5925-00-784-3742

5925-00-784-3742, 5925007843742 NSN Information

Request for Quote

Manufacturer Part Number(s):53-119-6-MG3, 53-119-MG3-7-5-416AC-2-400HZ, 53-119MG3-7-5A416VAC400C12, 53-119MG3-7-5A416VAC400C2, 9183733

FSC NIIN ITEM NAME
5925 007843742 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-784-3742 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
53-119-6-MG3 EATON CORP 74193 5 9 2
53-119-MG3-7-5-416AC-2-400HZ EATON CORP 74193 5 9 2
53-119MG3-7-5A416VAC400C12 EATON CORP 74193 5 9 2
53-119MG3-7-5A416VAC400C2 EATON CORP 74193 5 9 2
9183733 U S ARMY AVIATION AND MISSILE 18876 3 2 2

5925-00-784-3742 Characteristics

MRC Requirement Statement Characteristics
CPRJ TRIP RELEASE METHOD MAGNETIC ALL LOCATIONS
AAQL BODY STYLE MULTIPOLE-MULTIPLE ACTUATOR TYPE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.750 INCHES NOMINAL
AJEC BOSS HEIGHT 0.156 INCHES MAXIMUM
CPRY EXTERNAL ACTUATOR LINKAGE ARRANGEMENT ONE, TWO, AND THREE LINKED
CPRW ACTUATOR FUNCTION TRIP-RESET
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 3.250 INCHES NOMINAL
ADAT BODY WIDTH 3.078 INCHES MAXIMUM
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT
CPRQ RESET METHOD MANUAL
CPRP ULTIMATE TRIP TIME PER POLE IN SECONDS 1.000 MINIMUM AND 5.000 MAXIMUM ALL LOCATIONS
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 150.0 ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 7.5 AMPERES AC ALL LOCATIONS
FREQ FREQUENCY IN HERTZ 400.0 ALL LOCATIONS
TTQY TERMINAL TYPE AND QUANTITY 6 THREADED STUD
AXHR MOUNTING FACILITY TYPE AND QUANTITY 6 THREADED HOLE
THSD THREAD SERIES DESIGNATOR UNC
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 3.062 INCHES NOMINAL
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 4.500 MINIMUM AT 200 PCT AND 10.000 MAXIMUM AT 200 PCT ALL LOCATIONS
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 416.0 AC ALL LOCATIONS
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 500.0 AC ALL LOCATIONS
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 3 TOGGLE
CMLP THREAD QUANTITY PER INCH 32
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
ADAQ BODY LENGTH 3.734 INCHES MAXIMUM
AKPX POLE QUANTITY 3
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP ALL LOCATIONS
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
AEHA DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.031 INCHES NOMINAL
CPRX ACTUATOR POSITION DESIGNATION AT EACH POLE
AEBQ CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH 1.031 INCHES NOMINAL