| MRC |
Requirement Statement |
Characteristics |
| ABHP |
OVERALL LENGTH |
5.943 INCHES NOMINAL |
| AFSV |
III AVERAGE LIFE RATING IN HOURS |
250.0 |
| AHBB |
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ |
400.0 BLANK |
| CRDC |
III MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE |
800.0 VOLTS AT SEA LEVEL |
| STYL |
STYLE DESIGNATOR |
ROUND TERMINAL/TERMINALS ON OPPOSITE SURFACES |
| CQJX |
NOMINAL THREAD SIZE |
1.125 INCHES |
| CQGC |
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION |
130.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK |
| ADAQ |
BODY LENGTH |
4.000 INCHES NOMINAL |
| AHAQ |
SOURCE IMPEDANCE RATING PER FUNCTION |
50.0 OHMS BLANK |
| AKEJ |
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR |
UNEF |
| AHAS |
LOAD IMPEDANCE PER FUNCTION |
50.0 OHMS BLANK |
| CQRG |
III BODY MATERIAL |
METAL |
| AHBE |
MAXIMUM VOLTAGE DROP PER FUNCTION |
250.0 MILLIVOLTS DC BLANK |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING 3RD FUNCTION |
| ADAR |
BODY OUTSIDE DIAMETER |
2.000 INCHES NOMINAL |
| CQDW |
FUNCTIONAL TERMINAL TYPE AND QUANTITY |
1 TAB W/SCREW INPUT 1ST FUNCTION 1 TAB W/SCREW OUTPUT 2ND FUNCTION |
| AHBC |
OPERATING CURRENT RATING PER FUNCTION IN AMPS |
45.0 BLANK |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| TEST |
TEST DATA DOCUMENT |
97942-577R561H02 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| AFGA |
III OPERATING TEMP RANGE |
-65.0 TO 125.0 DEG CELSIUS |
| AECR |
III VIBRATION RESISTANCE RANGE IN HERTZ |
10.0 TO 2000.0 |
| CRST |
III BODY SURFACE TREATMENT |
TIN |