| Mfg. Part # | Mfg. Name | CAGE | RNCC | RNVC | ISC | MSDS | SADC | DAC | HCC |
|---|---|---|---|---|---|---|---|---|---|
| 2501459-469 | HONEYWELL INTERNATIONAL INC | 07187 | C | 1 | B | D | |||
| 4171595-398 | RAYTHEON COMPANY | 05869 | C | 1 | B | N | |||
| 538265-7203 | RAYTHEON COMPANY | 96214 | C | 1 | B | D | |||
| 57-757-378 | ASTEC AMERICA INC. | 08742 | C | 1 | B | F | |||
| 724-0631-050 | ROCKWELL COLLINS INC. | 95105 | C | 1 | B | D | |||
| 724-0639-720 | ROCKWELL COLLINS INC. | 13499 | C | 1 | B | D | |||
| 944205-6341 | NORTHROP GRUMMAN GUIDANCE AND | 06481 | C | 1 | B | F | |||
| MIL-R-55182/1 | MILITARY SPECIFICATIONS | 81349 | 4 | 1 | B | ||||
| RNC55H6341FM | MILITARY SPECIFICATIONS | 81349 | C | 1 | B | N | |||
| RNC55H6341FR | MILITARY SPECIFICATIONS | 81349 | C | 1 | B | N | |||
| RNC55H6341FS | MILITARY SPECIFICATIONS | 81349 | 2 | 2 | B | ||||
| RNR55H6341FS | MILITARY SPECIFICATIONS | 81349 | C | 1 | B | N |
| MRC | Requirement Statement | Characteristics |
|---|---|---|
| SR-1 | NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-55182/1 |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 175.0 |
| AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
| SR-1 | SPEC/STD CONTROLLING DATA | |
| AARG | RELIABILITY INDICATOR | ESTABLISHED |
| ADAQ | BODY LENGTH | 0.204 INCHES MINIMUM AND 0.281 INCHES MAXIMUM |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED |
| ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-55182/1 GOVERNMENT SPECIFICATION |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
| AARB | TERMINAL TYPE | WIRE LEAD |
| STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
| AAPP | ELECTRICAL RESISTANCE | 6.340 KILOHMS |
| ABPM | BODY DIAMETER | 0.078 INCHES MINIMUM AND 0.140 INCHES MAXIMUM |
| ABJT | TERMINAL LENGTH | 1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
| SR-1 | MANUFACTURERS CODE | 81349 |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.100 FREE AIR |
| SR-1 | DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RNC55H6341FS |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C |