5925-00-871-6497, 5925008716497 NSN Information

Request for Quote

Manufacturer Part Number(s):537-210-101, 62828-90037-7, 790-265, JA1S-D3-10-2, UPG1-1-62-103-90, W67-X2Q12-10

FSC NIIN ITEM NAME
5925 008716497 CIRCUIT BREAKER
INC ESDC HMIC
0013 P

5925-00-871-6497 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
537-210-101 TYCO ELECTRONICS CORPORATION 77342 5 9 2
62828-90037-7 AAI CORPORATION 97384 3 2 2
790-265 BOW INDUSTRIES OF VIRGINIA INC 53468 5 2 2
JA1S-D3-10-2 EATON CORP 74193 5 9 2
UPG1-1-62-103-90 AIRPAX CORP LLC 82415 5 9 2
UPG1-1-62-103-90 SENSATA TECHNOLOGIES MARYLAND INC 81541 5 2 2
W67-X2Q12-10 TYCO ELECTRONICS CORPORATION 77342 5 2 2

5925-00-871-6497 Characteristics

MRC Requirement Statement Characteristics
ADAT BODY WIDTH 0.750 INCHES NOMINAL
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 250.0 AC SINGLE LOCATION
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.530 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
APNQ III ARC QUENCHING METHOD MAGNETIC BLOWOUT
CPRW ACTUATOR FUNCTION TRIP-RESET
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES AC SINGLE LOCATION
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
CPRQ RESET METHOD MANUAL
CPRJ TRIP RELEASE METHOD MAGNETIC-HYDRAULIC SINGLE LOCATION
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 5000.0 AC SINGLE LOCATION
AFJN III FRAGILITY FACTOR MODERATELY RUGGED
AAQL BODY STYLE SINGLE POLE TYPE
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.660 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC
ADTV CASE MATERIAL PLASTIC
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.890 INCHES NOMINAL
TTQY TERMINAL TYPE AND QUANTITY 2 QUICK DISCONNECT, MALE
CMLP THREAD QUANTITY PER INCH 32
AJEC BOSS HEIGHT 0.130 INCHES NOMINAL
ADAQ BODY LENGTH 2.000 INCHES NOMINAL
BBRG III STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CQJX NOMINAL THREAD SIZE 0.138 INCHES
AKPX POLE QUANTITY 1
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 2.200 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
PKWT III UNPACKAGED UNIT WEIGHT 2.200 OUNCES
FREQ FREQUENCY IN HERTZ 50.0 OR 60.0 SINGLE LOCATION
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE