Home > Switches > FSC 5930 > 5930-00-644-2998

5930-00-644-2998, 5930006442998 NSN Information

Request for Quote

Manufacturer Part Number(s):2995-03LINE54, 3073-06PC47, 3073-21PC47, 3074-01PC47, 3095-03LINE353, 3678-219PC7, 564-3101-937728LINE34, 564-3803-1183565PC34, 571-4810-1301796PC7, AASK34263-5PC34, AASK34910-7PC34, K1-3101-1001284LINE353

FSC NIIN ITEM NAME
5930 006442998 SWITCH,THERMOSTATIC
INC ESDC HMIC
0045 P

5930-00-644-2998 MCRD (Master Cross Reference Data)

Mfg. Part # Mfg. Name CAGE RNCC RNVC ISC MSDS SADC DAC HCC
2995-03LINE54 ELECTRIC BOAT CORPORATION 96169 5 9 6
3073-06PC47 ELECTRIC BOAT CORPORATION 96169 5 9 6
3073-21PC47 ELECTRIC BOAT CORPORATION 96169 5 9 6
3074-01PC47 ELECTRIC BOAT CORPORATION 96169 5 9 6
3095-03LINE353 ELECTRIC BOAT CORPORATION 96169 5 9 6
3678-219PC7 ELECTRIC BOAT CORPORATION 96169 3 2 6
564-3101-937728LINE34 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
564-3803-1183565PC34 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
571-4810-1301796PC7 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
AASK34263-5PC34 CHROMALOX INC 65586 3 2 6
AASK34910-7PC34 CHROMALOX INC 65586 3 2 6
K1-3101-1001284LINE353 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
K1-3803-1002097PC34 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
K1-6202-1001237PC47 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
K1-6401-1001272PC47 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
K2-6202-1001257PC47 NAVAL SHIP SYSTEMS COMMAND 80064 3 2 6
X24173 DETROIT SWITCH INC. 19278 3 2 6

5930-00-644-2998 Characteristics

MRC Requirement Statement Characteristics
AWTN OPERATING TEMP RATING 220.0 DEG CELSIUS MAXIMUM AND -273.1 DEG CELSIUS MINIMUM
CTYM CONTACT ADJUSTMENT RANGE 70.00 TO 180.00 ACTUATION POINT DEGREES CELSIUS
CTYC CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 DC AT SEA LEVEL FIRST VOLTAGE 550.0 DC AT SEA LEVEL SECOND VOLTAGE
AEVV BULB DIAMETER 0.688 INCHES NOMINAL
AKBY TEMP SENSING ELEMENT TYPE CAPILLARY TUBE-BULB
CTYS CONTACT ADJUSTMENT TYPE EXTERNAL ACTUATION POINT SCREW
ABHP OVERALL LENGTH 7.500 INCHES NOMINAL
CTYX CONTACT STIMULUS RATING 3.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS
AFDS LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS 6.625 INCHES NOMINAL
AEVU BULB LENGTH 3.625 INCHES NOMINAL
AEVT CAPILLARY TUBE LENGTH 120.000 INCHES NOMINAL
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED
ABMK OVERALL WIDTH 4.459 INCHES NOMINAL
AFDV LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS 2.219 INCHES NOMINAL
AXGY MOUNTING METHOD BASE
CQYJ MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR
CTHF CONTACT LOAD CURRENT RATING 4.6 AMPERES RESISTIVE LOAD FIRST VOLTAGE 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE
ABKW OVERALL HEIGHT 2.875 INCHES NOMINAL