| MRC |
Requirement Statement |
Characteristics |
| ABPM |
BODY DIAMETER |
0.062 INCHES MINIMUM AND 0.124 INCHES MAXIMUM |
| STYL |
STYLE DESIGNATOR |
RADIAL TERMINAL EACH END |
| CBME |
(NON-CORE DATA) CUBIC MEASURE |
0.005 CUBIC INCHES |
| AAQZ |
INCLOSURE METHOD |
ENCAPSULATED |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AAQH |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS |
-55.0 TO 275.0 |
| AARB |
TERMINAL TYPE |
WIRE LEAD |
| AAQF |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER |
25.0 |
| PKWT |
III UNPACKAGED UNIT WEIGHT |
0.3 GRAMS |
| ABJT |
TERMINAL LENGTH |
1.375 INCHES MINIMUM AND 1.625 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
0.375 INCHES MINIMUM AND 0.437 INCHES MAXIMUM |
| AEFB |
POWER DISSIPATION RATING IN WATTS |
1.000 FREE AIR |
| AAPQ |
RESISTANCE TOLERANCE IN PERCENT |
-1.000 TO 1.000 |
| AAPE |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS |
-20.0 TO 20.0 |
| AAQG |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER |
275.0 |
| AAPP |
ELECTRICAL RESISTANCE |
1.700 KILOHMS |