MRC |
Requirement Statement |
Characteristics |
TTQY |
TERMINAL TYPE AND QUANTITY |
24 TAB, SOLDER LUG |
ADAQ |
BODY LENGTH |
3.630 INCHES MAXIMUM |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB |
MOUNTING HOLE DIAMETER |
0.148 INCHES MINIMUM AND 0.165 INCHES MAXIMUM SINGLE GROUP |
AXGY |
MOUNTING METHOD |
FLANGE AND UNTHREADED HOLE SINGLE GROUP |
FEAT |
SPECIAL FEATURES |
1PRIMARY,7 SECONDARY WINDINGS; ALL CURRENTS ARE SHOWN AS RECTIFIED; SECONDARIES 6 AND 7 ARE RATED THE SAME,0.1 AMP DC AT 16.5 AND 19.5 VOLTS RMS; 5TH SECONDARY IS 0.57 AMPS AT 21.50 AND 24.50 VOLTS RMS |
ACZD |
III TRANSFORMER WINDING CONNECTION TYPE |
DELTA-DELTA |
PKWT |
(NON-CORE DATA) UNPACKAGED UNIT WEIGHT |
2.250 POUNDS |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAU |
BODY HEIGHT |
1.630 INCHES MAXIMUM |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
CBME |
(NON-CORE DATA) CUBIC MEASURE |
16.3 CUBIC INCHES |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS |
WINDING OPERATING VOLTAGE |
21.50 AC VOLTS MINIMUM AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY 21.50 AC VOLTS MINIMUM AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY 21.50 AC VOLTS MINIMUM AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY 21.50 AC VOLTS MINIMUM AND 24.50 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY 184.00 AC VOLTS MINIMUM AND 216.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 7 SECONDARY SINGLE COMPONENT |
AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
AEHZ |
III MAXIMUM OPERATING TEMP |
130.0 DEG CELSIUS |
ABMK |
OVERALL WIDTH |
2.750 INCHES MAXIMUM |
CRBZ |
WINDING OPERATING CURRENT |
3.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 1.5 AMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 2.1 AMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 0.5 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
ACZX |
WINDING SHIELDING METHOD |
INTERNALLY SHIELDED SINGLE COMPONENT |
ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |