MRC |
Requirement Statement |
Characteristics |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
110.0 MILLIAMPERES DC SINGLE WINDING |
ABMK |
OVERALL WIDTH |
1.870 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
20 PIN ALL FUNCTIONS |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
1.0 AMPERES AC AND 1.0 AMPERES DC RESISTIVE LOAD |
ABKW |
OVERALL HEIGHT |
1.310 INCHES NOMINAL |
ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE MOUNTING FACILITY |
ABHP |
OVERALL LENGTH |
1.900 INCHES NOMINAL |
CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE MOUNTING FACILITY |
CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE MOUNTING FACILITY |
AKDX |
WINDING QUANTITY |
1 |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED STUD SINGLE MOUNTING FACILITY |
APCN |
COIL QUANTITY |
1 |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
AYSC |
PILE-UP MAIN CONTACT FORM ARRANGEMENT |
6C |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNA |
WINDING DC RESISTANCE RATING |
225.0 OHMS NOMINAL SINGLE WINDING |
AAJD |
THREAD CLASS |
2A SINGLE MOUNTING FACILITY |
APNP |
DUTY TYPE |
CONTINUOUS |