MRC |
Requirement Statement |
Characteristics |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
ABMK |
OVERALL WIDTH |
1.060 INCHES NOMINAL |
SR-1 |
MANUFACTURERS CODE |
94135 |
SR-1 |
SPEC/STD CONTROLLING DATA |
|
AAJD |
THREAD CLASS |
2B SINGLE MOUNTING FACILITY |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE SINGLE MOUNTING FACILITY |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP |
DUTY TYPE |
INTERMITTENT |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE MOUNTING FACILITY |
TTQY |
TERMINAL TYPE AND QUANTITY |
14 PIN ALL FUNCTIONS |
ABKW |
OVERALL HEIGHT |
2.930 INCHES NOMINAL |
CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
AKDX |
WINDING QUANTITY |
1 |
ADZC |
ENVIRONMENTAL PROTECTION |
WATER RESISTANT |
APCN |
COIL QUANTITY |
1 |
CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
20.0 MILLIAMPERES DC SINGLE WINDING |
ZZZT |
NONDEFINITIVE SPEC/STD DATA |
12-Z13001-9637 SPECIFICATION SHEET |
APNA |
WINDING DC RESISTANCE RATING |
800.0 OHMS NOMINAL SINGLE WINDING |
CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE MOUNTING FACILITY |
ABHP |
OVERALL LENGTH |
1.710 INCHES NOMINAL |
AYSC |
PILE-UP MAIN CONTACT FORM ARRANGEMENT |
1B2A AND 1B2A |
SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
12Z13001-9637 |