MRC |
Requirement Statement |
Characteristics |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYE |
III TRANSFORMER FUNCTION |
LINE |
ACZB |
FREQUENCY RATING |
300.0 HERTZ MINIMUM AND 3.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
AXGY |
MOUNTING METHOD |
FLANGE AND UNTHREADED HOLE SINGLE GROUP |
ADAT |
BODY WIDTH |
1.375 INCHES NOMINAL |
ADAU |
BODY HEIGHT |
1.625 INCHES NOMINAL |
ACYW |
IMPEDANCE RATING IN OHMS |
600.0 NOMINAL SINGLE COMPONENT SINGLE PRIMARY 3.2 NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
ACZH |
PRIMARY TO SECONDARY TURN RATIO |
1 TO 13-13/64 SINGLE COMPONENT |
SR-5 |
DESIGN CONTROL REFERENCE |
NL69780-1 |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
SR-5 |
MANUFACTURERS CODE |
28528 |
BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY AND 1 SECONDARY SINGLE COMPONENT |
TTQY |
TERMINAL TYPE AND QUANTITY |
4 TAB, SOLDER LUG |
ADAQ |
BODY LENGTH |
1.375 INCHES NOMINAL |
SR-5 |
THE MANUFACTURERS DATA |
|
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZF |
MAXIMUM TRANSFORMER POWER RATING |
2.0 WATTS SINGLE COMPONENT |
AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |