5950-00-053-8542 Characteristics

MRC Requirement Statement Characteristics
ACZP COIL FORM TYPE SOLID SINGLE COMPONENT
ADAR BODY OUTSIDE DIAMETER 0.167 INCHES MINIMUM AND 0.187 INCHES MAXIMUM
ACZR CORE CONSTRUCTION POWDERED SINGLE COMPONENT
AEHZ III MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS
BKPL RATING METHOD ELECTRICAL SINGLE COMPONENT SINGLE WINDING
ACYV INDUCTANCE RATING 1.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING
CRGS DC RESISTANCE RATING IN OHMS 17.500 SINGLE COMPONENT SINGLE WINDING
AFGS (NON-CORE DATA) MINIMUM SELF-RESONANT FREQUENCY 2.3 MEGAHERTZ
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRHJ QUALITY FACTOR 50 MINIMUM SINGLE COMPONENT SINGLE WINDING
AKNA INCLOSURE TYPE FULLY INCLOSED
CRBZ WINDING OPERATING CURRENT 105.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
ADAQ BODY LENGTH 0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 2 WIRE LEAD
CBBL FEATURES PROVIDED TINNED WIRE LEADS
CRLC (NON-CORE DATA) FREQUENCY AT WHICH INDUCTANCE AND QUALITY FACTOR APPLIES 790.0 KILOHERTZ
PKWT (NON-CORE DATA) UNPACKAGED UNIT WEIGHT 0.6 GRAMS