MRC |
Requirement Statement |
Characteristics |
THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE MOUNTING FACILITY |
ABKW |
OVERALL HEIGHT |
1.430 INCHES NOMINAL |
APNA |
WINDING DC RESISTANCE RATING |
500.0 OHMS NOMINAL SINGLE WINDING |
ABMK |
OVERALL WIDTH |
1.870 INCHES NOMINAL |
APNQ |
ARC QUENCHING METHOD |
INERT GAS |
ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE MOUNTING FACILITY |
AJSS |
FREQUENCY IN HERTZ |
60.0 NOMINAL |
AYSC |
PILE-UP MAIN CONTACT FORM ARRANGEMENT |
3C |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 THREADED STUD SINGLE MOUNTING FACILITY |
CSQJ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE |
0.938 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQYJ |
MOUNTING FACILITY PATTERN |
TRIANGLE SINGLE MOUNTING FACILITY |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
AKDX |
WINDING QUANTITY |
1 |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC |
CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
30.0 MILLIAMPERES AC SINGLE WINDING |
APCN |
COIL QUANTITY |
1 |
ABHP |
OVERALL LENGTH |
3.780 INCHES NOMINAL |
AAJD |
THREAD CLASS |
2A SINGLE MOUNTING FACILITY |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC RESISTIVE LOAD |
APNP |
DUTY TYPE |
CONTINUOUS |