MRC |
Requirement Statement |
Characteristics |
CTYM |
CONTACT ADJUSTMENT RANGE |
-100.00 TO 100.00 ACTUATION POINT DEGREES FAHRENHEIT |
CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
AXGY |
MOUNTING METHOD |
IMMERSION WELL |
CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE |
CSCF |
TERMINAL TYPE |
WIRE LEAD |
ADAV |
OVERALL DIAMETER |
0.625 INCHES NOMINAL |
SR-5 |
DESIGN CONTROL REFERENCE |
17121 |
CMLP |
THREAD QUANTITY PER INCH |
14 SINGLE PRESSURE CONNECTION |
AWTN |
OPERATING TEMP RATING |
-100.0 DEG FAHRENHEIT MINIMUM AND 100.0 DEG FAHRENHEIT MAXIMUM |
SR-5 |
THE MANUFACTURERS DATA |
|
CTYX |
CONTACT STIMULUS RATING |
1.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |
SR-5 |
MANUFACTURERS CODE |
73168 |
CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
230.0 AC AT SEA LEVEL FIRST VOLTAGE 230.0 DC AT SEA LEVEL SECOND VOLTAGE |
AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
ABHP |
OVERALL LENGTH |
4.781 INCHES NOMINAL |