| MRC |
Requirement Statement |
Characteristics |
| ABJT |
TERMINAL LENGTH |
1.500 INCHES NOMINAL |
| AAPE |
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS |
-500.0 TO 500.0 |
| AAQH |
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS |
-55.0 TO 235.0 |
| AAPP |
ELECTRICAL RESISTANCE |
1.780 KILOHMS |
| SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
RD60P1781G |
| SR-1 |
SPEC/STD CONTROLLING DATA |
|
| ADAQ |
BODY LENGTH |
0.594 INCHES NOMINAL |
| AAQZ |
INCLOSURE METHOD |
ENCAPSULATED |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| SR-1 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
MIL-R-11804/2 |
| AARB |
TERMINAL TYPE |
WIRE LEAD |
| STYL |
STYLE DESIGNATOR |
AXIAL TERMINAL EACH END |
| AAQF |
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER |
25.0 |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-11804/2 GOVERNMENT SPECIFICATION |
| SR-1 |
MANUFACTURERS CODE |
81349 |
| AAQG |
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER |
235.0 |
| AEFB |
POWER DISSIPATION RATING IN WATTS |
1.000 FREE AIR |
| ABPM |
BODY DIAMETER |
0.188 INCHES NOMINAL |
| AAPQ |
RESISTANCE TOLERANCE IN PERCENT |
-2.000 TO 2.000 |