MRC |
Requirement Statement |
Characteristics |
APNA |
WINDING DC RESISTANCE RATING |
245.0 OHMS NOMINAL SINGLE WINDING |
CBME |
III CUBIC MEASURE |
2.060 CUBIC INCHES |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
APNQ |
ARC QUENCHING METHOD |
AIR |
AGAV |
III END ITEM IDENTIFICATION |
4920-01-016-4639 |
CMLP |
THREAD QUANTITY PER INCH |
48 SINGLE MOUNTING FACILITY |
CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |
AAJD |
THREAD CLASS |
2B SINGLE MOUNTING FACILITY |
ABMK |
OVERALL WIDTH |
0.880 INCHES MAXIMUM |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
28.0 DC |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE MOUNTING FACILITY |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TTQY |
TERMINAL TYPE AND QUANTITY |
4 TAB, SOLDER LUG ALL FUNCTIONS |
AFJN |
III FRAGILITY FACTOR |
MODERATELY RUGGED |
ADTV |
III CASE MATERIAL |
METAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE SINGLE MOUNTING FACILITY |
CQJX |
NOMINAL THREAD SIZE |
0.099 INCHES SINGLE MOUNTING FACILITY |
AKSL |
III PURPOSE FOR WHICH DESIGNED |
GENERAL |
AAJF |
THREAD DIRECTION |
RIGHT-HAND SINGLE MOUNTING FACILITY |
AKDX |
WINDING QUANTITY |
1 |
CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
BBRG |
III STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
ABKW |
OVERALL HEIGHT |
1.410 INCHES MAXIMUM |
APCN |
COIL QUANTITY |
1 |
ABHP |
OVERALL LENGTH |
1.660 INCHES MAXIMUM |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
60.0 AMPERES DC RESISTIVE LOAD |
APNP |
DUTY TYPE |
CONTINUOUS |
ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |