MRC |
Requirement Statement |
Characteristics |
SR-1 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
M39016/6-128M |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ABHP |
OVERALL LENGTH |
1.180 INCHES MAXIMUM |
SR-1 |
SPEC/STD CONTROLLING DATA |
|
APNA |
WINDING DC RESISTANCE RATING |
700.0 OHMS NOMINAL SINGLE WINDING |
ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TTQY |
TERMINAL TYPE AND QUANTITY |
8 PIN ALL FUNCTIONS |
CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
ABKW |
OVERALL HEIGHT |
0.410 INCHES MAXIMUM |
SR-1 |
MANUFACTURERS CODE |
81349 |
CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
SR-1 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE |
MIL-PRF-39016/6 |
AKDX |
WINDING QUANTITY |
1 |
CRXH |
TIME DELAY |
0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
ABMK |
OVERALL WIDTH |
0.410 INCHES MAXIMUM |
APCN |
COIL QUANTITY |
1 |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
300.0 MILLIAMPERES AC AND 300.0 MILLIAMPERES DC RESISTIVE LOAD |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNP |
DUTY TYPE |
CONTINUOUS |