MRC |
Requirement Statement |
Characteristics |
CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES SINGLE MOUNTING FACILITY |
APNA |
WINDING DC RESISTANCE RATING |
4.45 OHMS NOMINAL SINGLE WINDING |
ABHP |
OVERALL LENGTH |
9.000 INCHES NOMINAL |
CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
600.0 AC |
ABMK |
OVERALL WIDTH |
5.500 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
8 THREADED STUD ALL FUNCTIONS |
CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
50.0 AMPERES AC RESISTIVE LOAD |
THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE MOUNTING FACILITY |
CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CMLP |
THREAD QUANTITY PER INCH |
20 SINGLE MOUNTING FACILITY |
CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
AKDX |
WINDING QUANTITY |
1 |
CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
0.5 AMPERES AC SINGLE WINDING |
CQYJ |
MOUNTING FACILITY PATTERN |
IRREGULARLY SPACED SINGLE MOUNTING FACILITY |
APCN |
COIL QUANTITY |
1 |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
9 THREADED STUD SINGLE MOUNTING FACILITY |
AAJD |
THREAD CLASS |
2A SINGLE MOUNTING FACILITY |
APNP |
DUTY TYPE |
CONTINUOUS |
ABKW |
OVERALL HEIGHT |
5.750 INCHES NOMINAL |
AJSS |
FREQUENCY IN HERTZ |
50.0 MINIMUM AND 60.0 MAXIMUM |