MRC |
Requirement Statement |
Characteristics |
ADAQ |
BODY LENGTH |
0.285 INCHES NOMINAL |
ABJT |
TERMINAL LENGTH |
1.500 INCHES NOMINAL |
CWQH |
DC LEAKAGE AT REFERENCE TEMP |
0.500 MICROAMPERES |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.200 INCHES NOMINAL |
CWNJ |
CAPACITIVE ELECTRODE MATERIAL |
TANTALUM |
CRTP |
TOLERANCE RANGE PER SECTION |
-10.00 TO 10.00 PERCENT SINGLE SECTION |
ADAU |
BODY HEIGHT |
0.170 INCHES NOMINAL |
ADAT |
BODY WIDTH |
0.225 INCHES NOMINAL |
AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 UNINSULATED WIRE LEAD |
AECQ |
ELECTRICAL POLARIZATION |
POLARIZED |
CWJK |
CASE MATERIAL |
PLASTIC |
AEBZ |
SCHEMATIC DIAGRAM DESIGNATOR |
ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL |
CQWM |
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION |
10.0 DC SINGLE SECTION |
CQJJ |
NONDERATED OPERATING TEMP |
-55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQBQ |
CAPACITANCE VALUE PER SECTION |
15.000 MICROFARADS SINGLE SECTION |
CWPM |
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT |
6.0000 |
AEBT |
TERMINAL DIAMETER |
0.025 INCHES NOMINAL |
AAQL |
BODY STYLE |
W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |